SpecificationModel: GXK-1500-C
Capacity: 1500VA / 900WUPS Type: Line Interactive
Waveform (Battery Mode): Simulated Sinewave
Control: Microprocessor-controlled with internal self-diagnostic technology
AVR: Boost and Buck (wide input range with two boost and one buck control)
Cold Start: Yes
Auto Restart: Yes (when AC recovers)Input:
Voltage: 220/230/240Vac
Voltage Range: 140–300Vac
Frequency Range: 50/60Hz (auto sensing)Output:
AC Voltage Regulation (Batt. Mode): ±10%
Frequency Range (Batt. Mode): 50/60Hz ±1Hz
Transfer Time: Typical 4–8ms
Waveform (Batt. Mode): Simulated SinewaveBattery:
Voltage: 24Vdc
Type & Quantity: 12V 9Ah × 2
Recharge Time: 6–8 hours to 90% capacityIndicators:
LED Version: AC Mode, Battery Mode, Overload, Fault
LCD Version: AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault, Battery LowProtection:
Short circuit, Overload, Overcharge, OverdischargeAlarm:
Battery Mode: Every 10 seconds
Low Battery: Every second
Overload: Every 0.5 second
Battery Replacement: Every 2 seconds
Fault: Continuous soundingManagement:
Communication Port: USB or RS232
OS Support: Windows 2000/2003/XP/Vista/2008/7, Linux, Unix, MACOperating Environment:
Humidity: 0–90% RH @ 0–40°C (non-condensing)
Noise Level: <55dBPhysical:
Dimensions (D × W × H): 380 × 158 × 198 mm
Net Weight: 10.1 kg